"Temp. C" - Maximum temperature value of the diagnosed unit recorded by the thermal imaging
camera.
"K50 I, A" - Current strength at terminal 50.
"K30 K45, mV" - Voltage at terminal 45.
The sequence of operations for starter diagnostics is as follows:
1. Place the starter on the workbench and secure the unit.
2. Attach the adapter to the positive terminal of the starter and connect the power cable "B+"
there. Connect the power cable "B-" to the unit's housing.
3. Connect the bench connector "50" with a cable to the control output of the starter solenoid
terminal 50, see Figure 30.
4. Connect the universal diagnostic cable K30 and K45 wires to the corresponding terminals of the
starter, see Figure 30.
5. In the main menu, select the starter testing mode, then choose the nominal voltage of 12 or
24 V.
6. Press the "AUTO" start button if a report needs to be generated. After the specified time, the
bench will stop the diagnostic process. Conclusions about the technical condition of the starter
and possible causes of malfunctions are drawn based on the graphs of voltage and current
changes.
6.1. If it's necessary to find a specific test result in the future, it's essential to save the
generated report under your name (for example, order number, client name, and date) in
another folder.
36
Figure 30. Terminal Locations on the Starter