Test bench MS005/MS005A
1.6. Limitations
To ensure the proper functioning of scripts, there are several limitations. For a better
understanding of these limitations, you can visit the "Manual Test" section and review the data
requirements.
Number of Revolutions: When setting the number of revolutions, it's important to understand that
the test stand can rotate from 0 to 3000 revolutions per minute. Setting a value outside this range
may lead to unstable test stand performance.
Current and Voltage: When configuring these parameters, it's essential to consider the alternator
type and its specifications. For instance, if you set a load of 300 for a alternator with a maximum
current of 100A, it can have extremely negative consequences.
K15 and Sense: These parameters are automatically enabled when entering the testing mode and
disabled when exiting. This should be taken into account to avoid writing unnecessary code. It
won't affect the process but may slow down execution.
2. Report generation
Generating a custom report is similar to creating a custom script.
To make the program use custom reports, you need to write them, name them accordingly (for
example, if it's a 12-volt lamp alternator, the name should be LAMP12.xlsx), and insert them into
the reports folder. The folder is located at C:\UserFiles\Reports.
In turn, it contains two subfolders, Advanced and Quick. These folders contain templates for
scripts. Accordingly, Advanced is for reports for advanced scripts, and Quick is for reports for quick
scripts. Ready-made reports should be inserted into these folders.
After conducting the test, a report will be automatically generated based on the created
template.
IMPORTANT: The program works in such a way that when a specific script is selected, the
corresponding report is also selected. For example, if we choose an advanced script for a 12-volt
lamp alternator (the path to it will be C:\UserFiles\Scripts\Advanced\LAMP12.txt), the
corresponding report located at C:\UserFiles\Reports\Advanced\LAMP12.xlsx will be used.
2.1. Creating your own report
A report template is created in Excel. You create a table where you record the values of variables
generated during the automatic test or constants. For example, if you want to display the
constants
и
you should make the following entry in the table:
#sCurrentTime
#sCurrentDate