Polaris Sportsman 450 HO Manual Del Propietário página 50

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

FEATURES AND CONTROLS
Instrument Cluster
Diagnostic Display Code Definitions
Component
Fan Relay Driver
Circuit
Ignition Coil Primary
Driver 1 (Front)
(MAG)
Fuel Pump Driver
Circuit
Oxygen Sensor 1
ECU Output Supply
Voltage 1
ECU Output Supply
Voltage 2
ECU Output Supply
Voltage 3
ETC Accelerator
Position Sensor
Outputs 1 & 2
Correlation
50
Diagnostic Codes
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Current Below Normal Or Open Circuit
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Current Below Normal Or Open Circuit
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Current Below Normal Or Open Circuit
Data Erratic, Intermittent Or Incorrect
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Bad Intelligent Device Or Component
Data Valid But Above Normal Operational Range - Most
Severe Level
Data Valid But Below Normal Operational Range - Most
Severe Level
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Data Valid But Above Normal Operating Range - Moderately
Severe Level
Data Valid But Below Normal Operating Range - Moderately
Severe Level
Data Valid But Above Normal Operational Range - Most
Severe Level
Data Valid But Below Normal Operational Range - Most
Severe Level
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Data Valid But Above Normal Operating Range - Moderately
Severe Level
Data Valid But Below Normal Operating Range - Moderately
Severe Level
Data Valid But Above Normal Operational Range - Most
Severe Level
Data Valid But Below Normal Operational Range - Most
Severe Level
Voltage Above Normal, Or Shorted To High Source
Voltage Below Normal, Or Shorted To Low Source
Data Valid But Above Normal Operating Range - Moderately
Severe Level
Data Valid But Below Normal Operating Range - Moderately
Severe Level
Data Erratic, Intermittent Or Incorrect
Condition
SPN
FMI
1071
3
1071
4
1071
5
1268
3
1268
4
1268
5
1347
3
1347
4
1347
5
3056
2
3056
3
3056
4
3056
12
3597
0
3597
1
3597
3
3597
4
3597
16
3597
18
3598
0
3598
1
3598
3
3598
4
3598
16
3598
18
3599
0
3599
1
3599
3
3599
4
3599
16
3599
18
65613
2

Hide quick links:

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Sportsman 570Sportsman 570 epsSportsman touring 570 epsSportsman x2 570Sportsman x2 570 eps

Tabla de contenido