7 Maintenance
CAUTION
Failure to follow the maintenance instructions
Risk of injuries due to changes in or loss of functionality and damage to the product
Observe the following maintenance instructions.
► NOTICE! Do not lubricate and grease the prosthetic joint.
► NOTICE! Repair work must be performed exclusively by manufacturer service.
► Arrange regular maintenance intervals with the patient depending on the level of use.
► Following an individual period for the patient to get accustomed to the prosthesis, check the
settings of the prosthetic joint and adapt them to the patient's requirements again as needed.
► The prosthetic components should be inspected after the first 30 days of use.
► Inspect the entire prosthesis for wear during normal consultations.
► Conduct annual safety inspections.
► As part of the safety inspections, inspect the prosthetic joint for wear and proper functionality.
Special attention should be paid to movement resistance, bearings and abnormal noises. Full
flexion and extension must be ensured at all times. Readjust as required.
8 Disposal
This product may not be disposed of with regular domestic waste in all jurisdictions. Disposal that
is not in accordance with the regulations of the country where the product is used may have a det­
rimental impact on health and the environment. Please observe the information provided by the
responsible authorities in the country of use regarding return, collection and disposal procedures.

9 Legal information

9.1 Liability
The manufacturer will only assume liability if the product is used in accordance with the descrip­
tions and instructions provided in this document. The manufacturer will not assume liability for
damage caused by disregarding the information in this document, particularly due to improper
use or unauthorised modification of the product.
9.2 CE conformity
The product meets the requirements of Regulation (EU) 2017/745on medical devices. The CE
declaration of conformity can be downloaded from the manufacturer's website.

10 Technical data

Reference number
Weight [g]
System height [mm]
Proximal system height up to the
alignment reference point [mm]
Distal system height up to the align­
ment reference point [mm]
Knee flexion angle
Proximal connection
Distal connection
Max. body weight [kg]
Mobility grade
32
3R106-Pro
885
163
-7
Pyramid Adapter
Tube Clamp (Ø 30 mm)
3R106-Pro=KD
910
187
16
170
175°
Lamination Anchor
125
2 + 3
3R106-Pro=ST
915
181
11
Threaded Connector
(M26x1.5)

Publicidad