English
11.3.1 Error type A or D
4
Fig. 51: Error type A, diagram
8
Fig. 52: Error type D, diagram
60
1
2
3
1
2
3
4
7
5
6
NOTE:
A 30-second time-out causes the display to revert to the status page
or error page.
NOTE:
Every error number has its own error counter, which counts the inci-
dence of the error within the last 24 hours and is reset after manual
acknowledgment, 24-hour continuous "mains on" or a new
"mains on".
Error type A (Fig. 51):
Program
Contents
step/query
1
• Error code is displayed
• Motor off
• Red LED on
• SSM is activated
• Error counter is incremented
2
> 1 minute?
3
Error acknowledged?
4
End; auto control resumes
yes
no
Error type D (Fig. 52):
Program
Contents
step/query
1
• Error code is displayed
• Motor off
• Red LED on
• SSM is activated
2
• Error counter is incremented
3
Is there a new type "A" fault?
4
> 1 minute?
5
Error acknowledged?
6
Is there a new type "A" fault?
7
Branching for error type "A"
8
End; auto control resumes
yes
no