Fig. 14: Installing the valves or blanking plate
AVENTICS | CL03, CL03-XL | R402000141–BAL–001–AF

8.2.6 Mounting the valve or blanking plate

14
19
17
18
1. Place the valve (17) or the blanking plate (16) on the new
subbase. Make sure the contacts are straight and that
the seal (18) is seated correctly. Press gently on the valve's
electrical connector end until the electrical contact is made.
2. Fasten the valve (17) or the blanking plate (16) using the two
self-tapping cross recessed screws (15, 13).
Tightening torque 1.1–1.3 Nm
Screwdriver PZD no. 1.
3. Turn the manual override on every valve to position 0 with
a screwdriver.