6.2

Applying voltage and compressed air

Uncontrolled movements due to incorrectly connected
compressed air lines in the valve system!
Incorrectly assembled compressed air lines with plug
connections could come loose when pressure is applied
to the valve system, resulting in injuries or damage
to the device.
Always check that the plug connections are effective
by gently pulling on the inserted line.
Risk of uncontrolled actuator movements when the
pneumatics are switched on!
Danger of injury if the system is in an undefined state
or if the manual overrides are set to position 1.
Put the system in a defined state before switching it on.
Set all manual overrides to position 0.
Make sure that no personnel are within the hazardous
zone when the compressed air supply is switched on.
1. Switch on the operating voltage.
2. Check the LED indications on the bus coupler if necessary
(see the respective manual).
3. Switch on the compressed air supply.