Conversion and Extension

8
Conversion and Extension
Risk of damage to the valve system!
Too high pressure on the exhaust air connection may damage
the unit.
Do not exceed 0.7 bar (for CL03) or 0.3 bar (for CL03-XL)
when connecting compressed air to the "Vent"
connection.
Disconnecting plugs when under voltage will damage
the device!
Large differences in potential occur when disconnecting
plugs under voltage, which could damage the device.
Make sure the relevant system component is not under
voltage before disassembling the device.
Loss of IP69K protection!
IP69K protection may be lost due to incorrectly applied
torques and poorly fitting seals.
Use the torques specified in these instructions.
Make sure that all seals are correctly seated in their
sealing slots,
Always check IP69K protection after conversions
(see "Checking IP69K protection and seals" on page 95).
The warranty only applies to the delivered configuration.
After a valve system conversion, the material number still
refers to the original configuration. Always carefully
document all changes to your valve system in your
technical documents.