Prerequisites
14
5
15
16
AVENTICS | CL03, CL03-XL | R402000141–BAL–001–AF
The following conversions and extensions can be made
to the valve system:
Assigning reserve valve positions (see page 85)
Adding further valve positions (see page 87)
Creating separate pressure zones by closing the air
channels with blanking plugs between the subbases
(see page 92)
Adjusting the internal and external pilot air (see page 93)
8.1

Assigning reserve valve positions

In order to assign reserve valve positions, the blanking plate
must be removed and a new valve mounted on the subbase.
The valve system is without pressure and voltage.

8.1.1 Removing the blanking plate

1. Remove the valve covers (5) from a reserve position
by undoing the three hexagon screws (14) using a 7 mm
wrench.
2. Turn both cross recessed screws (15) with a PZD no. 1
screwdriver and remove the blanking plate (16).