Aventics CL03 Instrucciones De Servicio página 78

Sistema de válvulas
Ocultar thumbs Ver también para CL03:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 207
76
AVENTICS | CL03, CL03-XL | R402000141–BAL–001–AF
Assembly
Danger due to high total current!
The valve system is supplied with 24 V DC supply voltage
with electrical isolation via a power pack according
to DIN EN 60742, classification VDE 0551.
When wiring, ensure that at least 2 GND pins are
connected to ensure that the total current from all valve
solenoids can be absorbed (20 mA per solenoid). All GND
pins in the multipole plug are bridged. This must
be observed in particular with a CL03-XL subbase
for parallel actuation of valves.
Protect the solenoid control with an external fuse.
Do not exceed the permissible current load of 1 A
per connector pin.
C
B
A
Fig. 8:
Connector pin assignment for up to 16 valves/32 solenoids
CAUTION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cl03-xl

Tabla de contenido