6. Approvals

The standard versions of SEG 60 Hz pumps have been approved
by CSA and the explosion-proof version holds a CSA and FM
type examination certificate no.: 3053414 (USA), 3053414C
(Canada).

6.1 Approval standards

CSA approval according to UL778 and C22.2 No. 108, No. 0.4,
No. 30, No. 145 and No. 60529. FM approval according to FM
3600, FM 3615 and FM 3650 and ANSI/IEC 60529.

6.2 Explanation to FM approval

The SEG 60 Hz pumps have the following explosion protection
classification: Class I, Division 1, Groups C and D hazardous
locations, T3C, IP68.
Standards
Code
Class I
Division 1
FM 3600
FM 3615
Group C and D Classification of gases
FM 3650
ANSI/IEC 60529
T3C
IP68

7. Safety

Warning
Pump installation in pits must be carried out by
specially trained persons.
Work in or near pits must be carried out according to
local regulations.
Warning
FM
Persons must not enter the installation area when the
atmosphere is explosive.
Warning
It must be possible to lock the mains switch in
position 0. Type and requirements as specified in
local regulations.
Warning
The use of this product requires experience with and
knowledge of the product.
Persons with reduced physical, sensory or mental
capabilities must not use this product, unless they
are under supervision or have been instructed in the
use of the product by a person responsible for their
safety.
Children must not use or play with this product.
8
Description
Explosive atmosphere
caused by gases or vapors
(permitted class)
Area classification
(permitted division)
Maximum surface
temperature is 275 °F and
320 °F (135 °C and 160 °C)
Enclosure class according
to IEC 60529.
For safety reasons, all work in pits must be supervised by a
person outside the pump pit.
It is advisable to make all maintenance and service
Note
Note
work when the pump is placed outside the pit.
Pits for submersible wastewater pumps contain wastewater with
toxic and/or disease-causing substances. Therefore, all persons
involved must wear appropriate personal protective equipment
and clothing and all work on and near the pump must be carried
out under strict observance of the hygiene regulations in force.
Warning
Make sure that the lifting bracket is tightened before
attempting to lift the pump. Tighten if necessary.
Carelessness during lifting or transportation may
cause injury to personnel or damage to the pump.
The following warnings and notes also appear in a label
(delivered with the pump). Place the label near the control panel.
Warning
Risk of electric shock.
Do not remove cord and strain relief. Do not connect
conduit to pump.
Warning
Risk of electric shock.
This pump has not been approved for use in
swimming pools or marine areas.
Warning
To reduce risk of electric shock, see installation and
operating instructions for guidance in proper
installation.
Warning
To reduce risk of electric shock, install only on a
circuit protected by a ground-fault circuit interrupter
(GFCI).
Note
Note
Acceptable for indoor and outdoor use.
Note
Note
Submersible pump.
Provide suitable motor protection based on the
Caution
electric ratings.
Caution
This pump has been tested with water only.
Use with approved motor protective circuit breaker
matching motor input in full-load amperes with
Caution
overload element(s) selected or adjusted in
accordance with control instructions.