Double combustion
Some models of the stoves include a double combustion. With this system we
get a second preheated entry air inside the combustion chamber. This allows a
second combustion of the not burnt gases in the first combustion that achieves
a high performance efficiency, a great fuel saving and reductions in pollutant
emissions.
-
The models Sydney, Petra, Monaco, Preston, Derby and Bury have this
air intake control for the double combustion under the door, which is the
same than the secondary air intake control. This control is placed on the
right and the movement is from inside to outside and vice versa. The
operation to outside increase the air input (see drawing D8).
The combustion is not always stable. In fact, it can be affected by the weather conditions or the outside temperature. This modifies the draw
of the chimney. For this reason, our stoves have a baffle plate (or double baffle plate)
WARNING!
The lack of the baffle plate causes an excessive draw. This causes a fast combustion, excessive wood consumption and
the overheating of the equipment.
Due to safety reasons during the transport, the baffle plate is not assembled. You will find it inside the combustion chamber. To place it
properly, follow the next steps:
Frontal models:
D10
In models Petra, Sydney and Monaco the baffle plate must be rested on the side supports of the combustion chamber and you have to fit on
the groove where the air of the double combustion goes off.
NOTE: some models with oven does not have a baffle plate.
"Cold hands" handle
(Only models Alhambra, Sena and Oxford)
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
-
There are many others models such as Irlanda, Ávila, Tudela, Vitoria,
D9
Alhambra, Sena, Soria, Oxford, Etna, Ordesa, Bremen, Preston, Derby, Bury
and Zamora whose entry of preheated air exists but it is not adjustable. The
air supply is usually made by little drillings on the back wall of the combustion
chamber (see drawing D9).
Baffle plate
The baffle plate is a fundamental part for the proper operation of the stove. It
must be placed in the right position and the stove must not be used without
the baffle plate. This would invalidate the warranty.