2.1.

SPECIFICATIONS ACCORDING TO THE MODEL

2.1.1.

SYDNEY-T AND PETRA-T

The models Sydney-T and Petra-T have a 270 m3/h fan to improve the heat distribution by
the ventilation.
The start and the control of the ventilation is made by the regulator knob placed on the right
back side of the stove (see drawing D20).
This regulator has the following functions:
-
OFF position: the fan is turned off when there is no combustion inside the chamber due to the stove is
provided with a thermostat that controls the fan according to the temperature of the stove.
-
ON position: the fan is turned on although there is no combustion inside the chamber.
In any case, you can choose the fan speed by the regulator.
TURBINE CONNECTION:
In the right back side of the stove you will find the cable that connects to the electricity network.
It is advisable do not cut it in the entire length because this section is useful when needed by changes in electrical components inside.
It is obligated the correct connection of the installation to earth connection.
The installation of the system might be done by skilled labour and qualified under the current rules.
REPLACEMENT OF THE TURBINE:
The replacement of any electrical component will be done
by the front of the stove. With this you do not have uninstall
the stove and you have to follow the next steps (see
drawing D21).
-
First of all, you will have to screw out the screws in
both sides of the fan protection.
-
Once you have removed the protection you can
access to the thermostat, the plug connections and
the fan will be available.
-
In order to remove the fan you will have to elevate it
and release it from its fixation to the stove.
-
Disconnect and replace the damaged element and
reattach everything such as before.
D22
OUTSIDE AIR INTAKE
The models Petra and Sydney have
the choice to take the primary and
secondary entry air from an adjacent
room (or even from outside of the
house) or the same room where the
stove is installed.
The primary air intake of these models is on the rear side of the stove, so in case that the stove is not connected with the
outside it will be necessary a minimum distance of 6-8 cm to have an enough air supply to the combustion. In the case
you choose the primary air intake from the outside or an adjacent room it will be enough connecting this entry by a 120
mm diameter driving with the chosen location. Note that a driving too long or with deviations (elbows), cause a big lost of
charge, therefore could cause some combustion problems. (See drawing D22).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
In the models Oxford, Zamora, Preston, Derby, Bury and
Ordesa, to make the change of the collar you have to
follow the next steps:
1.
First of all, remove the baffle plate.
2.
Remove the vermiculite pieces (only model
Oxford).
3.
Later, screw out the cover and the collar,
change their position and screw them again in the new
position (see drawing D19).