Ordesa; Etna And Bury 9 / Bury 14; Installation And Safety Instructions - Bronpi SYDNEY Instrucciones De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

D29
2.1.5.

ORDESA

Inside of the combustion chamber you can find a piece called "ash catcher". This piece is useful to avoid the fall of the ashes to the floor
when you open the door of the stove. To place it properly, follow the next steps:
1-
We must match the hooks of the piece with the groove of the stove. To this, rotate slightly the piece.
2-
When the piece is inserted on the grooves, drop it from its own weight to rest in his final position (see drawing D31).
In the stove, it is included a handle to remove the ash pan to avoid burns (see drawing D30).
D30
2.1.6.

ETNA AND BURY 9 / BURY 14

The model Etna has a door on the right side whose function is to load fuel (see drawing D32).
In the Etna stove, it is included a handle to remove the ash pan which is hidden behind the lower door (see drawing D33).
D32
3.

INSTALLATION AND SAFETY INSTRUCTIONS

The way of installing the stove will affect the safety and the proper operation. For this reason, it is recommendable that the installation is
carried out by people who are qualified and informed about the compliance with the installation and safety norms. If a stove is not properly
installed it may cause serious damage.
Before the installation, follow the next verifications:
Make sure that the floor can sustain the weight of the equipment and make a proper isolation in the case that it is made of flammable
material (wood) or a material that can be affected by a thermal shock (plaster cast, for example).
If the equipment is installed on a floor which is not completely refractory or inflammable such as parquet, carpet, etc, it is necessary
to replace this part or introduce a fire-resistant base so that it protrudes out the fireplace 30 cm. Example of materials include steel
flooring, glass base or any other type of fire-resistant material.
Make sure that there is proper ventilation in the place where it is installed (air intake) (see section 5 of the manual).
Avoid the installation in places where there are collective ventilation pipes, hoods with or without extractor, B type gas equipments,
heat pumps or equipments that can cause that the draw of the stove is not good if they are used at the same time.
Make sure that the smoke duct and the pipes used for the chimney are suitable for the operation of the stove.
We recommend that you call your fitter in order to check both the chimney as well as the air flow for the combustion.
This product can be installed near the walls as long as the they comply with the following requirements:
The fitter must assure that the wall is completely made of brick masonry, thermo-clay block, concrete, bricks, etc, and that it is coated
by materials that can support high temperature.Therefore, for any other type of material (drywall, wood, non-ceramic glass, etc), the
fitter must provide sufficient insulation or keep a minimum safety distance to the wall of 80-100 cm.
Keep any flammable or heat sensitive materials (furniture, curtains, and clothing) at a minimum distance of about 100cm, including the
area in front of the loading door. Measurements below the minimum distances should not be used.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
21