If self-learning is correct, OK is displayed on the motorisation screen.
If self-learning has failed, KO is displayed on the motorisation screen. Check the following before restarting self-learning:
•
the gate runs correctly,
•
there is nothing obstructing the photoelectric cells (if fi tted).
If self-learning is interrupted, return the gate to the closed position and restart self-learning.
If the slowing down speed is subsequently changed, self-learning must be carried out again.
AT THIS STAGE IN THE INSTALLATION, THE MOTORISATION IS OPERATIONAL.
MOTORISATION OPERATION
See pages 2 and 3 in the user's manual.
CONNECTING ADDITIONAL DEVICES
24 V integrated fl ashing amber light
(ref. 9 014 552)
Photoelectric cells
With autotest
24V
24V
ac/dc 0V
ac/dc 0V C NC NO
1
2
1
2
CE
Activate the cell autotest function: tESt Phot to ON in the LoGIc
menu.
Copyright © 2008 Somfy SAS. All rights reserved.
3
4
5
CR
Without autotest
24V
24V
ac/dc 0V
ac/dc 0V C NC NO
1
2
3
4
1
2
CE
Deactivate the cell autotest function: tESt Phot to OFF in the LoGIc
menu.
Elixo 500 24 V
5
CR
9