3 41 01 120 21 0.book Seite 7 Dienstag, 10. März 2009 10:19 10
FSC1.6X/FSC1.6Q/FSC2.0Q
Emission values for sound and vibration (Two-figure – specifications as per ISO 4871)
Sound emission
Measured A-weighted sound power level
L
(re 1 pW), in decibels: 90
wA
Measuring uncertainty K
A-weighted emission pressure power level
measured at the workplace L
in decibels: 79
Measuring uncertainty K
REMARK: The sum of the measured emis-
sion value and respective measuring inaccu-
racy represents the upper limit of the
values that can occur during measuring.
Wear ear protection!
Measured values determined in accordance
with the corresponding product standard.
Extension cord
If the use of an extension
CAUTION
cable is required, its length
and conductor cross-section must be ade-
quate for the applicational case, in order to
prevent a voltage drop in the extension cable,
power loss and overheating of the power
tool. Otherwise, the extension cable and
power tool are liable to electrical danger,
and the working efficiency is impaired.
Recommended dimensions of extension
cords at an operating voltage of 120 V – sin-
gle-phase a. c., with only one power tool
FSC 1.6X/FSC 1.6Q/FSC 2.0Q connected:
Vibrations
Classification of FEIN
application tools accor-
, in decibels: 3
wA
ding to vibration class
VC0
(re 20 µPa),
pA
VC1
, in decibels: 3
pA
VC2
VC3
VC4
VC5
*These values are based on a work cycle
consisting of no-load and full-load opera-
tion of the same duration.
For information on the vibration class
assigned to the application tool, please see
the enclosed data sheet 3 41 30 213 06 2.
Cord Size in A.W.G.
18
Cord Length in Feet
25
acceleration*
Wire Sizes in mm
16
14
0.75
1.5
Cord Length in Meters
100
150
30
60
en
Weighted
2
< 2.5 m/s
2
< 8 ft/s
2
< 5 m/s
2
< 16 ft/s
2
< 7 m/s
2
< 23 ft/s
2
< 10 m/s
2
< 33 ft/s
2
< 15 m/s
2
< 50 ft/s
2
> 15 m/s
2
> 50 ft/s
2
2.5
120
7