Installation - Sime 30 PC Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2

INSTALLATION

IT
ES
The boiler must be installed in a fixed loca-
tion and only by specialized and qualified
firms in compliance with all instructions
PT
contained in this manual.
Furthermore, the installation must be in
GB
accordance with current standards and
regulations.
2. 1
BOILER ROOM
The "FORMAT.zip 30 PC" version boilers
can be installed in any domestic environ-
ment without any location restrictions or
comburent air requirements.
2.3
INSTALLATION PLATE
To mount the installation plate supplied as
an optional extra (kit code 8081215), follow
the instructions written below (fig. 4):
– Fix the connecting sheet to plate (A) and
lower plate (B).
– With the template complete, fix plate (A)
to the wall using the two boiler support
screws.
– Check that plate (B) is perfectly horizon-
tal using a spirit level.
– Connect the bends or connecting val-
ves supplied in the optional kit to the
system pipes.
2.3. 1
System connection unions
The following optional accessories are avail-
able to facilitate water and gas connection
of the boiler with the heating system:
– curve kit, code 8075423
– cock kit, code 8091806
– kit for replacement of other brands' wall-
mounted units, code 8093900.
Detailed instructions for assembly of the
unions are provided with the kits.
2.4
CONNECTING UP SYSTEM
To protect the heat system from damaging
corrosion, incrustation or deposits, before
installation it is extremely important to
clean the system using suitable products
such as, for example, Sentinel X300 or
X400.
Complete instructions are provided with
the products but, for further information,
you may directly contact GE Betz.
For long-term protection agains corrosion
and deposits, the use of inhibitors such as
Sentinel X100 is recommended after clea-
ning the system.
It is important to check the concentration
of the inhibitor after each system modifica-
tion and during maintenance following the
manufacturer's instructions (specific tests
are available at your dealer).
The safety valve drain must be connected
to a collection funnel to collect any dischar-
ge during interventions. If the heating
system is on a higher floor than the boiler,
72
install the on/off taps supplied in kit code
8091806 on t he heating sy s t em
delivery/return pipes.
WARNING:
Failure to clean the heat system or add
an adequate inhibitor invalidates the devi-
ce's warranty.
Gas connections must be made in accor-
dance with current standards and regula-
tions. When dimensioning gas pipes from
the meter to the module, both capacity
volume (consumption) in m
3
density must be taken into account.
The sections of the piping making up the
system must be such as to guarantee a
supply of gas sufficient to cover the maxi-
mum demand, limiting pressure loss
between the gas meter and any apparatus
being used to not greater than:
– 1.0 mbar for family II gases (natural gas);
– 2.0 mbar for family III gases (butane or
propane).
An adhesive data plate is sticked inside the
front panel; it contains all the technical data
identifying the boiler and the type of gas for
which the boiler is arranged.
380
335
70 70 70 70
U
E
G
M
2.4. 1
Connection of
condensation
water trap
The drip board and its water trap must be
connected to a civil drain through a pipe
with a slope of at least 5 mm per metre to
ensure drainage of condensation water.
The plastic pipes normally used for civil
drains are the only type of pipe which is
appropriate for conveying condensation
to the building's sewer pipes.
/h and gas
2.4.2
Filter on the gas pipe
The gas valve is supplied ex factory with an
inlet filter, which, however, is not adequate to
entrap all the impurities in the gas or in gas
main pipes.
To prevent malfunctioning of the valve, or in
certain cases even to cut out the safety devi-
ce with which the valve is equipped, install an
adequate filter on the gas pipe.
2.6
SYSTEM FILLING
This operation must be performed with the
A
B
R
Fig. 4