conveyed through a flexible or rigid pla-
stic pipe around 100 to 150 mm in dia-
meter, and condensation must be sipho-
PT
ned off at the foot of the pipe.
The usable height of the water trap must
GB
be at least 150 mm.
2.8.3
Separate-pipes roof outlet
The accessories to be used for this type of
installation and some of the connecting
systems that may be adopted are illustra-
ted in fig. 11.
There is the possibility of doubling the air-
intake and smoke-outlet pipes and then brin-
ging them back together again so as to
obtain a concentric discharge by using the
doubler fitting (9 fig. 11).
For this type of discharge the sum of the
maximum
rectilinear
allowed for the pipes must not exceed 7
mm H
O.
2
When calculating the lengths of pipe, take
into account the parameters given in the
Table 1.
2.9
FORCED DISCHARGE
(Type B22/52)
This type of discharge can be configured
with kit code 8089912. For instructions on
how to mount the kit, see point 2.8.
Protect the suction with the optional acces-
sory (code 8089501).
The accessory can be mounted using an ø
80 extension and a 50 mm long block,
which must be fitted on the air inlet. At this
point, it is possible to insert the accessory
and fix it to the block with the screws provi-
ded (fig. 12).
Kit (code 8089912) is supplied with the
76
development
inlet diaphragm, which must be used depen-
ding on the maximum load loss permitted,
as shown in figure 8/a.
The maximum permitted load loss should
not exceed 7 mm H
As the maximum length of the duct is deter-
mined by adding the load losses of the single
accessories, refer to Table 1 for calcula-
tions.
2. 1 0
POSITIONING THE
KEY
1
Separate pipes kit code 8089912
2
90° elbow MF code 8077450 (6 pz.)
3
90° elbow MF with take-off points code 8077452
4 a Extension L. 1000 code 8077351 (6 pz.)
4 b Extension L. 500 code 8077350 (6 pz.)
6
Int.-est. ring kit code 8091500
7
Inlet terminal code 8089500
9
Doubler fitting code 8091400
10
Tile with articulated joint code 8091300
11
Roof outlet terminal L. 1381 code 8091204
NOTE
Before connecting accessories, it is always
advisable to lubricate the internal part of
the gaskets with silicon products. Avoid
using oils and greases.
The outlet terminals for forced-draught
appliances may be located in the external
perimeter walls of the building.
O.
To provide some indications of possible solu-
2
tions, Table 3 gives the minimum distances
to be observed, with reference to the type
of building shown in fig. 13.
2. 1 1
cod. 8089501
Fig. 11
OUTLET TERMINALS

ELECTRICAL CONNECTION

Fig. 12