Technical data
Parameter
Operating voltage for
load U(+LA)/U(+LB)
Safety outputs (LA / LB,
2 semiconductor out-
puts, p-switching, short
circuit proof, electrically
decoupled)
1)
U(LA)/U(LB)
HIGH U(LA)
HIGH U(LB)
LOW U(LA)/U(LB)
Switching current
External fusing
U(+LA)/U(+LB)
Safety circuit
Utilisation category to
EN 60947-5-2
Classification to
EN 60947-5-3
Door signal output
(semiconductor output,
p-switching, short cir-
cuit proof)
Output voltage
Load rating
1)
Values for a switching current of 50 mA without consideration of the cable
length.
Value
min.
typ.
18 V DC
U(+LA)
–1.5 V DC
U(+LB)
–1.5 V DC
0 V DC
1 mA
400 mA medium slow-bow
DC-13 24 V 400 mA
PDF-M
0,8 x U
B
V DC
Operating Instructions
T4000 Compact
max.
27 V DC
U(+LA)
V DC
U(+LB)
V DC
1 V DC
400 mA
U
V DC
B
20 mA
8009212/TF93/2010-03-29