Technical Data Evaluation Unit T4000 Compact - SICK T4000 Compact Instrucciones De Servicio

Ocultar thumbs Ver también para T4000 Compact:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operating Instructions
T4000 Compact
Tab. 3:
Technical data
evaluation unit
T4000 Compact
8009212/TF93/2010-03-29 © SICK AG • Industrial Safety Systems • Germany • Subject to change without notice
Technical data
8.2.1 Technical Data evaluation unit T4000
Compact
Parameter
Housing material
Dimensions
Weight
Ambient temperature at
U
= 24 V DC
B
Enclosure to
IEC/EN 60529
Protection class
according to
IEC/EN 61558
Installation position
Type of connection
Operating voltage U
(reverse voltage proof,
stabilised, residual
ripple < 5 %)
The approval in accor-
dance with
specifies
Current consumption
Switching load accor-
ding to
External fusing –
Operating voltage
min.
Plastic PBT V0 GF30
In accordance with
EN 60947-5-2
–20 °C
Plug connector M12, 8-pole,
18 V DC
B
Operate only with UL Class 2
voltage supply
24 V DC, Class 2
0.25 A
Value
typ.
max.
0.4 kg
+55 °C
IP 67
III
any
shielded
24 V DC
27 V DC
80 mA
8 A
8
Chapter
155

Publicidad

Tabla de contenido
loading