Operating Instructions
T4000 Compact
WARNING
Tab. 6:
Technical data
actuator T4000-
1KBR
8009212/TF93/2010-03-29 © SICK AG • Industrial Safety Systems • Germany • Subject to change without notice
Technical data
8.5.2 Technical data actuator T4000-1KBR
The typical response range applies if the sur-
rounding material is non-metallic.
If the surrounding material is metallic, the switch-
on distance and the switching hysteresis will be
lower.
Parameter
Housing material
Dimensions
Weight
Ambient temperature
Enclosure rating
Installation position
Power supply
1)
Dwell time
Operating range at center
2)
offset = 0
– Safe switch-off distance
s
ar
– Switch-on distance
– Safe switch-on distance
s
ao
– Switching hysteresis
1)
The dwell time is the period for which the actuator must remain inside or
outside the response range.
2)
The values do apply for non-flush mounting of actuator.
3)
Mounting on aluminium is not permitted.
Value
min.
typ.
Plastic PC
Ø20 mm x 2,1 mm
0.0008 kg
–25 °C
–
IP 67
Sensing face opposite read head
Inductive via read head
0.5 s
–
–
–
–
21 mm
19 mm
–
2 mm
3 mm
8
Chapter
max.
+70 °C
–
41 mm
3)
–
–
–