Description and Technical Data
Appliance Description
§
End segment with limit rocker switch (SGR and SPV)
The limit rocker switch is fitted in the end segment of the frame surface at the end of the belt. In case of
mechanical strain the limit rocker switch will be pressed down, thus generating an electric signal, and the
belt will stop moving. After releasing the limit rocker switch the belt will start moving automatically. The
switch mechanism is protected on all sides against ingress of liquids and dirt particles.
§
Light barrier (SGR and SPV)
The light barrier prevents the further movement of trays beyond the end of the belt; depending on the
setting, with or without crockery items.
The light barrier is fitted on the end of the belt as a height restriction (crockery detector) inserted along
with the reflector into covers made of stainless steel. They are fastened facing each other and flush on
the bar of the edge of the well. Adjust the optic sensors after consultation; the minimum height is approx
0.2'' (5 mm) below the edge, the maximum heigh is approx. 0.8'' (20 mm) above the edge. Place the light
barrier at the middle, about 13.8'' (350 mm) from the end of the belt.
§
Foot switch (SPV only)
The foot switch allows to start and stop the conveyor belt. It is used in addition to the operating elements
on the control panel.
§
Patient card drawer (SPV only)
The patient card drawer holds up patient cards and can be removed quickly and completely without any
tools. It is fitted under the conveyor belt at the beginning of the belt system. The maximum load of 25 kg
may not be exceeded.
§
Rotary table (SPV only)
Use the rotary table that is fitted at the beginning of the belt at about 9.8" (250 mm) from the front side to
keep your records or other information. The rotary table and the support tube rotate independently of
each other. The rotary table may only be moved when there are no objects on its surface and there are
no people around it. The maximum load of about 5 kg may not be exceeded. The rotary table is
delivered disassembled. To assemble the rotary table, insert the support tube into the plastic part.
§
Hinged board (SPV only)
The hinged board is an additional storing shelf and is fitted flush at the end of the belt. The board can be
folded up by lifting it slightly up and raising it to an angle of 90°. It is not permitted to locate any objects
on the board when folding it down. The maximum load of about 10 kg may not be exceeded in order not
to risk any material damage.
§
Sorting bridges (SGR only)
The sorting bridge is used for safe storage on the opposite belt casing. The sorting bridge can be folded
by lifting it lightly up and raising it to an angle of 90°. The unfolded sorting bridge is flush with the belt
casing. The hinged design without a chute but with a sound absorbing panel attached at the bottom can
be fitted on the belt upon agreement. The maximum load of the sorting bridge is 25 kg.
4330053_A7
Section 3
Page 17
Belt Conveyor System
SGR | SPV