Troubleshooting and Repair

Safety Measures

6
Troubleshooting and Repair
6.1
Safety Measures
DANGER
CAUTION
6.2

Instructions regarding Fault Repair

Servicing may be carried out by authorised specialists only.
Defective components may only be replaced with
replacement of individual components.
In the event of after-sales service and when ordering spare parts specify always the data given in the rating
plate.
Regular inspections and maintenance of the appliance prevent disruptions to operation and ensure safety.
6.3

Fault and Action Table

Only a specialist staff authorised by HUPFER® may perform troubleshooting work.
Fault
The conveyor system does not run
The speed cannot be adjusted
4330053_A7
Hazardous electrical voltage
Electrical current can pose a considerable threat to life and physical well-
being and may lead to injuries.
Before performing troubleshooting, take the conveyor system out of operation
and secure it against unauthorised reactivation.
Rotating machine parts
There is an indirect risk of injuries of the fingers caused by being pulled into
the appliance and crushing.
Never reach into the hazardous area of the conveyor system while examining
the system for faults and performing troubleshooting. Ensure that your fingers
do not get caught under the belt when performing work at the conveyor
system.
HUPFER
Cause
Defective on site fuses
Defective mains connecting cable or
mains plug
Defective switch device
Emergency Stop button has been
pressed
(the green ring cannot be seen)
Main switch is not turned on
Defective fine fuses
Energy optimisation device switches
on
Foot switch is not activated
Defective potentiometer or control
unit
®
original parts. The modular design simplifies the
Measures
Fuses to be checked and replaced
by a qualified electrician, if required
Have the disruption checked and
repaired by a qualified electrician.
Have the disruption checked and
repaired by a qualified electrician.
Unlock the Emergency Stop button
(the green ring is visible)
Turn on the main switch
Fault to be checked and repaired by
a qualified electrician
Fault to be checked and repaired by
a qualified electrician
Press the foot switch
Fault to be checked and repaired by
a qualified electrician
Section 6
Page 29
Belt Conveyor System
SGR | SPV