Quick User Manual
State
Description
If an error occurs, the inverter will automatically stop operation,
trigger the AC relay and show "Error xxx" on the LCD with the
indicator red (xxx is the error code).
Error xxx
Once the error is cleared in recovery time, the inverter will
automatically resume running. The recovery time can be set
via the App.
If the device is in standby mode for more than 10 minutes, please
check:
 Whether the insolation is sufficient and the PV connection is correct.
 If no anomaly is found, disconnect the DC switch and the main switch
to restart.
If it still does not work, contact SUNGROW.
Viewing the Active Error/Warning
If the status on the main screen is "Error xxx",
Touch ENT to view the active error code.
If the inverter is running with a warning, Touch
ENT to view the active warning code.
Only one error or warning can be displayed on
this screen. Refer to "6.2 Errors on the App
or LCD Screen" for a solution.

5.2 Menu Structure

For the running information, the power value indicated represents the average
value during the time interval.
The energy yields displayed are indicative only. For the actual yields, please
refer to the energy meter of electric utility company.