EN
– The Webasto Live charging station also meters the
plug-in cycles of the charge coupling for service
purposes and after 10,000 plug-in cycles, displays
a note on the web interface that an electrician
needs to inspect the plug contacts on the charge
coupling for any signs of wear. If any signs of
wear are discovered, the electrician must replace
the affected charging cables with genuine
Webasto spare parts.
– Do not attach extension cables or adapters to the
charging cable.
– Remove the charging cable by pulling on the char-
ging coupling only.
– Never clean the charging station with a high-pres-
sure cleaner or similar device.
– Switch off the power supply before cleaning the
charging sockets.
– The charging cable must not be subjected to any
strain during use.
– Ensure only persons who have read these operat-
ing instructions have access to the charging sta-
tion.
WARNING
- When not in use, store the charging cable in the desig-
nated holder and lock the charging coupling in the remote
dock. Loosely wind the charging cable around the remote
dock making sure the cable does not touch the floor.
- You must make sure that the charging cable and coup-
ling cannot be driven over, trapped and are protected
from all other hazards.
2.3
Safety information for installation
– You must comply with the locally applicable re-
quirements regarding electrical installations, fire
protection, safety regulations, and escape routes
at the intended installation location.
– Only use the supplied installation material.
– When open, ESD (electrostatic discharge) precau-
tions must be taken properly to avoid electrostatic
discharge.
2
– When handling electrostatically sensitive boards,
wear grounded antistatic wrist straps and properly
observe ESD safety precautions. Wrist straps must
only be used when mounting and connecting the
loading unit. Wrist straps must never be worn on
a live Webasto Pure.
– Electricians must be properly grounded during in-
stallation of the Webasto Pure.
– Do not install the Webasto Pure in an explosion
sensitive area (Ex Zone).
– Install the Webasto Pure in such a way that the
charging cable does not block any passageways.
– Do not install the Webasto Pure in areas subject to
ammonia or air containing ammonia.
– Do not install the Webasto Pure in a location
where falling objects may damage the it.
– The Webasto Pure is suitable for use indoors as
well as outdoors.
– Do not install the Webasto Pure in the vicinity of
water jets, such as car-wash installations, high-
pressure cleaners or garden hoses.
– Protect the Webasto Pure against damage caused
by sub-zero temperatures, hail or similar. We
would like to refer you to our IP protection class at
this juncture (IP54).
– The Webasto Pure is suitable for use in areas
without access restrictions.
– Protect the Webasto Pure from direct sunlight.
The charging current may be reduced at high tem-
peratures, or charging may be disabled com-
pletely. The operating temperature range is -30 °C
to + 55°C.
– The installation location of the Webasto Pure
should ensure that vehicles cannot inadvertently
collide with it. Protective measures must be imple-
mented if the possibility of damage cannot be
ruled out.
– Do not put the Webasto Pure into operation if it
has been damaged during installation; a replace-
ment will be required.
Safety information for electrical
2.4
connection
WARNING
– Comply with the nationally applicable require-
ments pertaining to electrical installations, fire
protection, safety regulations and escape routes
at the intended installation location. Observe the
applicable national installation regulations.
– Each charging station must be protected with its
own line circuit breaker and residual current cir-
cuit breaker. See Requirements at the installation
location.
– Make sure that the electrical connections are de-
energised before connecting the charging station
to the power supply.
– Do not connect a vehicle during initial start-up of
the charging station.
– Make sure that the correct supply cable is used
for the power connection.
– Do not leave the charging station unattended
with the cover open.
– Change DIP-switch settings only with the power
off.
– Register with the power supply company as re-
quired.
Safety information for initial start-up
2.5
WARNING
– Initial start-up of the charging station must be car-
ried out only by an electrician.
– Prior to initial start-up, the electrician must check
that the charging station has been connected
correctly.
– Before starting-up the charging station, check
the charging cable, charging coupling and the
charging station for visible damage. The charging
OI II Webasto Pure