Installation
All installation must be carried out by a competent person or qualified electrician. Before connecting
the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate.
Direct Connection
The appliance must be connected directly to the mains using an omnipolar circuit breaker with a
minimum opening of 3mm between the contacts.
The installer must ensure that the correct electrical connection has been made and that it complies
with the wiring diagram.
The cable must not be bent or compressed.
Regularly check the power plug and power cord for damage. If the supply cord is damaged, it must
be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a
safety hazard.
WARNING: This is a Class I appliance and MUST be earthed.
This appliance is supplied with a 3 core mains cable coloured as follows:
Brown = L or Live
Blue = N or Neutral
Green and Yellow = E or Earth
EUR
N
(Blue)
L
(Brown)
(Green/Yellow)
To avoid the risks that are always present when you use an electrical appliance it is important that
this appliance is installed correctly and that you read the safety instructions carefully to avoid misuse
and hazards. Please keep this instruction booklet for future reference and pass it on to any future
owners. After unpacking the appliance please check that it is not damaged. If in doubt, do not use the
appliance but contact Customer Services - see end of Care & maintenance section for details.
ATL10383 100000038_28E5 35CM Island Glass Hood R.indd 29
N
N
L
L
UK
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
FUSE ON
USE A 3AMP FUSE