7
Chapter
152
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice
Technical data
Parameter
Testinput
LOW
HIGH
EMC protection
requirements
LED indicators
Value
min.
typical
0 V DC
–
15 V DC
–
to EN 60947-5-3
STATE LED green: Normal mode
blinking:
operation
OUT
LED yellow: Actuator
detected
ERROR LED red:
– Test input activated
– Internal circuitry error
– Invalid Teach-in operation
– EMC interference
Operating Instructions
T4000
max.
2 V DC
U
B
Teach-in
8009704/XN71/2013-09-04