Technical data
Parameter
Connection sensor
T4000-DNAC
Line length T4000-DNAC

7.3.4 Notes on installation

The sensor connecting cable must not be
increased in length. Inline connection not
permitted.
Actuator and sensor must be attached so that:
–The distance between the sensing faces is less
than or equal to the switch-on distance 0,8 x S
(see Technical data) with the safety guard
closed.
–They are not used as a mechanical stop.
–They are positively connected to the safety
guard; e.g. by using the enclosed safety screws.

7.3.5 Safety precautions

With flush installation of the sensor and/or
actuator, the switching distance will change
depending on the installation depth and the
material of the safety guard.
The safety guard must be designed so that the
distance S
(safe switch-off distance) does not
ar
allow for a gap that will increase the possibility of
exposure to the hazard.
The relay outputs are safely deactivated, even in the
case of an internal component failure, at the safe
switch-off distance S
min.