Operating Instructions
T4000
6
Commissioning and operation
WARNING
WARNING
8009704/XN71/2013-09-04
Commissioning and operation
Before the machine or system protected using the
non-contact safety switch T4000 is placed in
operation for the first time, it must be checked
and approved by qualified safety personnel. The
test must be documented.
After any change to the non-contact safety switch
T4000 or its components, or to the protective
device monitored, or after test and repair work,
the safety function must again be checked and
approved by qualified safety personnel. The test
must be documented.
6.1
"Teach-in" actuator function
The actuator must be assigned to the evaluation
unit with the Teach-in function before the system
forms a functional unit.
During the Teach-in operation, the safety outputs
and the door signal output are set to LOW, i.e. the
system is in the safe state.