of equipment.
LEVELLING AND SECURING -
see SECTION IMAGES - REFE-
RENCES c).
Position in the work place (see opera-
tion and environmental limit conditions
permitted), previously made suitable, of
the appliance.
The tasks of levelling and securing
include: adjustment of the appliance
as a single independent unit. Place a
spirit level on the structure (detail D).
Adjust the levelling feet (detail E) ac-
cording to the indications provided by
the level.
Perfect levelling is achieved by
adjusting level and feet on the
width and depth of the appliance.
"SERIES" ASSEMBLY / see SECT.
IMAGES - REF. d).
Remove the knobs and unscrew the
screws for the fixing of the panel on
both appliances (detail F).
Flammable walls / The mini-
mum distance of the appliance
from the side walls must be 10
cm and from the rear wall must be 20
cm. If it is lower, insulate the walls clo-
se to the appliance with fireproof and /
or insulating treatments.
Before proceeding with the
operations, see "General sa-
fety information".
These operations must be
performed by qualified and
authorised operators, in ac-
cordance with the laws in force and
using the appropriate materials de-
scribed.
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
POSITIONING AND HANDLING
including hot combustion fumes coming
out of the chimney (see identification
with High temperatures warning label
and description on page 2), to people
who transit and / or operate within the
work environment.
To place the equipment adherent each
other perfectly (part G). Level the equi-
pment as described above (detail E).
Remove the protective caps (part H2).
Insert the screws in their housings and
lock the two structures with the locking
nuts (part H1-H3).
Replace the protective caps between
the devices (part H2).
Repeat, if necessary, the sequence of
leveling and fixing operations for the
remaining equipment.
INTRODUCTION
(OPTIONAL) see SECT. IMAGES
- REF. d) / In order to introduce the
terminal, position it and fix it with the
equipped screws provided (detail L1).
Once the described operations have
been carried out, position again the
panels and knobs of the different ap-
pliances in the respective housings.

POWER SUPPLY CONNECTIONS

The appliance is delivered
without electric mains supply
cable, without pipes for con-
nection to the water, drainage and
gas networks.
GASPOWER CONNECTIONS
see SECT. IMAGES - REF. e).
Features of the installation site /
- 10 -
Install the appliances so as to
exclude any accidental contact
with high temperature surfaces,
OF
TERMINAL
4.
-