Beretta Mynute Sinthesi 25 C.S.I. Manual De Instalación Y De Uso página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
Mynute Sinthesi 25 C.S.I.
Seasonal energy efficiency class for heating
Parameter
Nominal output
For heating and combined boilers: useful heat output
At nominal heat output and in high
temperature mode (*)
At 30% of nominal heat output and in
low temperature mode (**)
Auxiliary electric consumption
With full load
With partial load
In standby
For combined heating appliances:
Load profile declared
Daily electricity consumption
Annual electricity consumption
(*) in high temperature mode: 60°C on return and 80°C on delivery
(**) in low temperature mode: for condensing boilers 30°C, for low temperature boilers 37°C, for other heating appliances 50°C of return temperature
Seasonal energy efficiency class for heating
Parameter
Nominal output
For heating and combined boilers: useful heat output
At nominal heat output and in high
temperature mode (*)
At 30% of nominal heat output and in
low temperature mode (**)
Auxiliary electric consumption
With full load
With partial load
In standby
For combined heating appliances:
Load profile declared
Daily electricity consumption
Annual electricity consumption
(*) in high temperature mode: 60°C on return and 80°C on delivery
(**) in low temperature mode: for condensing boilers 30°C, for low temperature boilers 37°C, for other heating appliances 50°C of return temperature
B
Symbol
Value
Unit
Pnominale
24
kW
P4
24.4
kW
P1
7.5
kW
elmax
90.0
W
elmin
28.4
W
PSB
2.0
W
XL
Qelec
0.220
kWh
AEC
48
kWh
Mynute Sinthesi 29 C.S.I.
B
Symbol
Value
Unit
Pnominale
28
kW
P4
28.3
kW
P1
8.7
kW
elmax
75.0
W
elmin
23.9
W
PSB
2.0
W
XL
Qelec
0.207
kWh
AEC
45
kWh
Energy efficiency class for water
heating
Parameter
Seasonal energy efficiency for heating
For heating and combined boilers: efficiency
At nominal heat output and in high
temperature mode (*)
At 30% of nominal heat output and in
low temperature mode (**)
Other parameters
Heat losses in standby
Energy consumption of the pilot flame
Annual energy consumption
Sound power level inside
Nitrogen oxide emissions
Energy efficiency for water heating
Daily fuel consumption
Annual fuel consumption
Energy efficiency class for water
heating
Parameter
Seasonal energy efficiency for heating
For heating and combined boilers: efficiency
At nominal heat output and in high
temperature mode (*)
At 30% of nominal heat output and in
low temperature mode (**)
Other parameters
Heat losses in standby
Energy consumption of the pilot flame
Annual energy consumption
Sound power level inside
Nitrogen oxide emissions
Energy efficiency for water heating
Daily fuel consumption
Annual fuel consumption
Mynute Sinthesi C.S.I.
A
Symbol
Value
Unit
ηs
86
%
η4
87.7
%
η1
90.1
%
Pstby
40.0
W
Pign
-
W
QHE
82
GJ
LWA
50
dB
mg/
NOx
149
kWh
ηwh
81
%
Qfuel
24.122
kWh
AFC
18
GJ
A
Symbol
Value
Unit
ηs
86
%
η4
87.9
%
η1
89.6
%
Pstby
40.0
W
Pign
-
W
QHE
95
GJ
LWA
50
dB
mg/
NOx
146
kWh
ηwh
82
%
Qfuel
23.811
kWh
AFC
18
GJ
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mynute sinthesic 29 c.s.i.Mynute sinthesi 29 c.s.i

Tabla de contenido