6. Maintenance
Using the same tool, tighten the bolt (J)
7.
to move the rotor over the saft, bringing
the knives closer to the counter knife.
Move the rotor until the distance between
8.
the knives and the counter knife is up to
0.5 mm;
Re-tighten the bolt (D);
9.
Mount the knife that has been removed
10.
from the rotor;
After adjusting, rotate the rotor manually
by turning one full turn. Observe carefully
if there is no contact between the knives
and the counter knife. If necessary, repeat
the adjustment, observing the maximum
clearance of 0.5 mm between the knives
and the counter knife.
Operate the machine with a friction of
knives with counter knife will damage the
machine and could result in the release of
fragments that could hit people and cause
an accident involving personal injury.
The use of PPE (Personal Protective
E q u i p m e n t ) i s m a n d a t o r y d u r i n g
operation, maintenance and adjustment
of the machine. Wear suitable gloves and
eye protection. Take special care when
handling knives and counter knife, these
components have sharp areas that can
cause injury if handled without proper
protection and care.
Finally, replace the rotor cover (J), the
11.
sharpener cover (B).