17. Grundfos Eye

The operating condition of the pump is indicated by the Grundfos
Eye on the control panel. See fig. 50, pos. A.
Fig. 50 Grundfos Eye
Grundfos Eye
A
Indication
No lights on.
Two opposite green indicator lights rotating in
the direction of rotation of the motor when
seen from the non-drive end.
Two opposite green indicator lights
permanently on.
One yellow indicator light rotating in the
direction of rotation of the motor when seen
from the non-drive end.
One yellow indicator light permanently on.
Two opposite red indicator lights flashing
simultaneously.
The green indicator light in the middle flashes
quickly four times.
The green indicator light in the middle flashes
continuously.
The green indicator light in the middle is
permanently on.
The green indicator light in the middle flashes
quickly while the Grundfos Go Remote is
exchanging data with the motor. It will take a
few seconds.
Description
Power off.
Motor not running.
Power on.
Motor running.
Power on.
Motor not running.
Warning.
Motor running.
Warning.
Motor stopped.
Alarm.
Motor stopped.
Remote control with the Grundfos GO Remote via
radio.
The motor is trying to communicate with the
Grundfos GO Remote. The motor in question is
highlighted in the Grundfos GO Remote display to
inform the user of the location of the motor.
When the motor in question is selected in the
Grundfos GO Remote menu, the green indicator
light in the middle will flash continuously. Press
on the motor control panel to allow remote control
and data exchange via the Grundfos GO Remote.
Remote control with the Grundfos GO Remote via
radio.
The motor is communicating with the Grundfos GO
Remote via radio connection.
Remote control with the Grundfos GO Remote via
infrared light.
The motor is receiving data from the Grundfos GO
Remote via infrared communication.