Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
the message, « put the clamp in short-circuit » disappears
4
The result is displayed for 10 sec:
A : « Ok »: cables are in good working condition.
After 10 sec. Gysflash 75-12 HF will automatically revert back to the main menu
B : « Check cable / Start: calibrate »: The Gysflash 75-12 HF offers either to check or calibrate
the cables using the start/stop button. If the user does not launch the calibration operation
within 10 seconds the unit will revert back to the main menu
« Check cables »: After switching off the charger, clean the contacts then check the charge
cables and change them if necessary. After this is done, restart the « check cables » cycle.
Start « calibration »: this function enables the Gysflash to calibrate the cables connected to
the machine (length and section) to ensure that the current delivered at the clamps is
correct. To calibrate, put the clamps in short-circuit, press Start/Stop, the Gysflash 75-12
HF displays « calibration OK » then goes back to the main menu.
Charge End
After the battery has been charged, 'Floating' mode continues to deliver a current to the battery to
maintain a maximum charge.
This function is initially active. To disable this function go into the settings menu, select "Restart"
and use the battery type selection button to toggle Float/OFF
Restart
The automatic restart function works in showroom and charge mode - it enables an automatic
restart for the charger in the event of unexpected power loss.
This function is initially active. To disable this function, go into the settings menu, select "Restart",
and use the battery type selection button to toggle ON/OFF
PROTECTION
The Gysflash is protected against short-circuits, polarity inversions and engine starts. It has an anti-
spark feature which prevents sparks whilst connecting the Gysflash to the battery. The Gysflash will
not deliver current if there is no battery detected (no voltage in the clamps). The charger is protected
by 3 x 40A fuses (GYS Ref. 054554) or 1 x 80A (Ref: 051369) - check existing fuse.

TROUBLESHOOTING

PROBLEMS
Machine displays count-down
(HH:MM)
Machine displays :
« EXCESSIVE CONSUMPTION »
+ The LED warning is illuminated
Machine displays:
« BATTERY ERROR »
+ The LED warning is illuminated
Machine displays:
« BATTERY Out of Order »
+ The LED warning is illuminated
CAUSES
Timer mode activated
A consumer has been left on
(eg : Headlights)
The charger has detected a non
12V
The battery is in short circuit or
damaged.
The charger has detected a 6V
battery
SOLUTIONS
Normal display in Timer mode - to
deactivate the timer, follow 'Timer'
instructions in Setting menu - set
value to 00H
Switch off electrical consumers (i.e
headlights). It is also recommended to
use
the
machine
with
unconnected
Charger is specified for 12V
Use a compatible charger
Replace the Battery
Charger not speciified for 6V
Use a compatible charger
battery
15

Publicidad

Tabla de contenido
loading

Tabla de contenido