requirements for the operation of automatic doors and gates. In particular,
these standards require the use of force limiting and safety devices (sensing
ground plates, photocell barriers, hold-to-run operation, etc.) intended to
detect persons or objects in the operating area and prevent collisions in all
circumstances.
The installer is required to measure impact forces and select on the control
unit the appropriate speed and torque values to ensure that the door or gate
ROGER TECHNOLOGY cannot be held responsible for any damage or injury
caused by the installation of incompatible components which compromise
the safety and correct operation of the device.
If the hold-to-run function is active, the installer will have the obligation
to check the maximum stop distance or the alternative use of the rubber
deformable edge, the closing speed or the gate and in general all aspects
indicated by the applicable regulations. Moreover, please not that if the
automation system control and operation and the command type and the
use type must comply with the UNI EN 12453 standard, prospectus 1 (with
the following restrictions: type A or B command or type 1 or 2 use).
In case of hold-to-run operation, remove any potential persons away from
the range of action of the automation system's moving parts; the direct
commands must be installed at a minimum height of 1.5 m and must not be
accessible to the public; moreover, unless the device is key operated, they
must be located with a direct view to the motorised part and far from the
moving parts.
the dangerous areas.
Each installed device must have a visible indication of the motorised door or
or subsequent revisions
A switch or an omnipolar cut-off switch with a contact opening of at least 3
mm must be installed on the mains power line; put the cut-off switch in OFF
position and disconnect any buffer batteries before performing any cleaning
or maintenance operations.
Ensure that an adequate residual current circuit breaker with a 0.03 A
threshold and a suitable overcurrent cut-out are installed upstream the
electrical installation in accordance with best practices and in compliance
with applicable legislation.
When requested, connect the automation to an effective earthing system
that complies with current safety standards.
The electronic parts must be handled using anti-static conductive wrist
straps with grounding wire.
Only use original spare parts when repairing or replacing products.
The installer must provide the user with complete instruction for using the
59