Special Parameters For Reversible Series - Roger Technology B70/1DC Manual De Instrucciones

Ocultar thumbs Ver también para B70/1DC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 160
15

Special parameters for Reversible series

The BH30/R series (REVERSIBLE) is a family of digital brushless motor units for sliding gates
weighing up to 800 kg and dedicated exclusively to residential and industrial applications.
REVERSIBLE technology makes it possible to open and close the gate, without power supply, without
releasing the motor even.
When the gate is moved manually, in the absence of supply voltage, the rotation of the motor supplies
power to the control panel, the display turns ON and the message "
hand with moderation.
The control unit allows independent management of speed, acceleration, deceleration and the safety devices used
in the system.
force to impede manual movement of the gate.
As a result, prolonged operation may drain the battery when operating under battery power.
than 3 cm is detected, the control unit initiates a position recovery procedure (see chapter 20).
NOTE: Even though it is a REVERSIBLE unit, the motor is equipped with a lock release system.
The additional parameters for enabling REVERSIBLE technology are indicated as follows.
Selecting automation system model
WARNING!
The automation system will no longer function effectively and it will not be possible to diagnose faults.
N.B.: in the event of a reset to restore the default parameters, this parameter must be set again manually.
BH30/600 - IRREVERSIBLE motor for gate leaves up to 600 kg.
BH30/800 - IRREVERSIBLE motor for gate leaves up to 800 kg.
BH30/500/HS - BH30/600/HS High Speed IRREVERSIBLE motor for gate leaves up to 600 kg
BM30/400 - IRREVERSIBLE motor for gate leaves up to 400 kg.
BM30/300/HS - High Speed IRREVERSIBLE motor for gate leaves up to 400 kg.
BH30/804/R - High Speed REVERSIBLE motor for gate leaves up to 800 kg.
Setting deceleration during opening
Setting deceleration during closing
01= the gate decelerates near the limit switch ... 05= the gate decelerates long before the limit switch.
Setting start acceleration during opening
Setting start acceleration during closing
01= the gate accelerates rapidly at start of manoeuvre ... 05= the gate accelerates slowly and progressively at
start of manoeuvre.
Setting opening speed
N.B.: the speed setting range is subdivided into 5 equal segments.
Setting closure speed
N.B.: the speed setting range is subdivided into 5 equal segments.
01= 7 m/min (minimum speed) ... 05= 20 m/min (maximum speed).
N.B.: to set the constant speed deceleration space, see parameters
84
" appears. WARNING! Move the gate by
and
on Chapter 13.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fw p2.00 b70/1dc

Tabla de contenido