Setting photocell mode during gate opening (FT2)
DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate opening.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed opening when the
photocell is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate closes when the photocell is cleared.

Setting photocell mode during gate closing (FT2)

DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate closure.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed closing when the
photocell is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate opens when the photocell is cleared.
Photocell (FT2) mode with gate closed
This parameter is not visible if
If the photocell is obstructed, the gate cannot open.
The gate opens when an open command is received, even if the photocell is obstructed.
The photocell sends the gate open command when obstructed.
Enable close command 6 s after activation of photocell (FT1-FT2)
This parameter is not visible if
opening, the 6 secs. count starts when the wings are completely open.
Disabled.
Enabled. When the photocell barrier FT1 is crossed, a close command is sent 6 seconds later.
Enabled. When the photocell barrier FT2 is crossed, a close command is sent 6 seconds later.

Setting motor stop distance

01= faster deceleration/shorter stop distance ... 05= slower deceleration/longer stop distance.
Selecting installation position of motor relative to gate (seen from interior
side)
NB:
PROG key until
appears on the display, then repeat the acquisition procedure.
N.B.: in the event of a reset to restore the default parameters, this parameter must be set again manually.
Motor installed on left.
Motor installed on right.
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when opening.
Contact with 8k2 resistor. The gate reverses only when opening.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when closing.
Contact with 8k2 resistor. The gate reverses only when closing.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
,
or
is set.
or
is set. NOTE: in the case of photocells being blanked during
COS1
COS2