Parameters Menu - Roger Technology B70/1DC Manual De Instrucciones

Ocultar thumbs Ver también para B70/1DC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 160
13

Parameters menu

PARAMETER
PARAMETER
VALUE
Selecting automation system model
WARNING! If this parameter is not set correctly, the automation system may not function properly.
N.B.: in the event of a reset to restore the default parameters, this parameter must be set again manually.
BH30/600 IRREVERSIBLE motor for gate leaves up to 600 kg
BH30/800 IRREVERSIBLE motor for gate leaves up to 800 kg
BH30/500/HS - BH30/600/HS - IRREVERSIBLE HIGH SPEED motor for gate leaves up to 600 kg (see
chapter 14 "Special parameters for High Speed series")
BM30/400 IRREVERSIBLE motor for gate leaves up to 400 kg
BM30/300/HS - IRREVERSIBLE HIGH SPEED motor for gate leaves up to 400 kg (see chapter 14 "Special
parameters for High Speed series")
BH30/804/R - REVERSIBLE motor for gate leaves up to 800 kg (see chapter 15 "Special parameters for
High Speed series")
Automatic closure after pause time (from gate completely open)
Disabled.
From 1 to 15 of gate closure attempts after photocell is triggered.
Once the number of attempts set is reached, the gate remains open.
Automatic gate closing after mains power outage
Disabled. The gate does not close automatically when mains power is restored.
Enabled. If the gate is NOT completely open, when mains power is restored, the gate closes after a 5 second
"position recovery" mode (see chapter 20).
Selecting step mode control function (PP)
Open-stop-close-stop-open-stop-close...
Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer restarts if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and prevents
the gate from closing when not required.
If automatic closing is disabled (
Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer does NOT restart if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and prevents
the gate from closing when not required.
If automatic closing is disabled (
.
Open-close-open-close.
Open-close-stop-open.
Flashing warning signal for 1 to 10 seconds prior to every manoeuvre.
Condominium function for partial open command (PED)
Disabled. The gate opens partially in step mode: open-stop-close-stop-open...
Enabled. Partial commands are ignored during gate opening.
), the condominium function automatically attempts a closing manoeuvre
), the condominium function automatically attempts a closing manoeuvre
). The gate closes in
.
75

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fw p2.00 b70/1dc

Tabla de contenido