CONTACT
20
19(ANT) Antenna connector for slot-in radio receiver board.
22(ORO)
21(COM) Clock timer contact input (N.O.).
23(AP)
21(COM) Open control signal input (N.O.).
24(CH)
21(COM) Close command input (N.O.).
25(PP)
21(COM) Step by step mode command input (N.O.).
26(PED)
21(COM) Partial open control signal input (N.O.).
27(+24V)
28(COM) Power feed for external devices. See technical characteristics.
29(LAM)
28(COM)
ENC
FC
SB
RECEIVER CARD
BATTERY
CHARGER
B71/BC
2x12 Vdc
1,2 Ah.
or
2x12 Vdc 4,5 Ah
66
DESCRIPTION
Use RG58 if an external antenna is used; maximum recommended length: 10 m.
N.B.: do not make joints in cable.
When the clock function is active, the gate opens and remains open.
At the end of the programmed time set with the external device (clock), the gate closes.
The function of this command is determined by parameter
IMPORTANT: persistent activation of the opening command prevents automatic re-
closure; the automatic reclosure time count is resumed when the opening command
is released.
The function of the control is determined by parameter
Set by default to 50% of completely open position.
Connecting B72/BRAKE - B72/BRCL power unit for BH30
Reversible
BM30
rameter
Connector for connecting to encoder installed on motor.
WARNING! Always disconnect from electrical power before disconnecting or
connecting the encoder cable.
In case of encoder replacement, repeat the acquisition procedure.
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector (N.C. contacts) for connecting mechanical limit switch (see
tail E) or magnetic limit switch (see
switch is activated. IMPORTANT: repeat the travel acquisition procedure after each
adjustment to the limit switches.
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector (N.C.) for connecting release contact. If the motor release handle is ope-
ned, the gate stops and no command signals are accepted.
Once the release handle is closed again, if the gate is in an intermediate position, the
controller unit initiates the position recovery procedure (see chapter 18).
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector for plug-in radio receiver board.
The control unit has two radio remote control functions by default:
The programming buttons PR1 and PR2
In the event of a mains power loss, the controller unit is powered by the batteries. When
battery power is used,
minimum permissible limit. In this case,
and the controller unit accepts no commands.
WARNING! the batteries must always be connected to the electronic controller unit in
order to charge. Periodically (at least every 6 months), check that the battery is in good
working order.
Two battery kits are available:
• Two 12 V DC, 1.2 Ah batteries installed in the automation system itself.
• Two 12 V DC, 4.5 Ah batteries installed in an external case.
For more information, refer to the installation manual for the B71/BC battery charger.
WARNING: it is recommended to use AGM type batteries.
(24 Vdc - duty cycle 50%).
- detail F). The gate stops when the limit
(Battery Low) is shown on the display
.
.
BH30
.