PROBLEM
ALARM
The gate does not
open or close.
Acquisition
procedure does not
complete correctly.
Remote control has
limited range and
does not work while
automated gate is
moving.
not working.
Gate open indicator
lamp does not work.
Gate does not
perform desired
manoeuvre.
The control unit is
switched off and
does not start.
POSSIBLE CAUSE
Inverter thermal overload circuit
breaker tripped.
Motor power control anomaly
detected
Flat batteries.
(btLO)
Release device open.
Motor control anomaly detected Repeat the acquisition procedure. If the problem
Problems at the encoder circuit
or at the connection cable.
Motor calibration failed.
TEST button pressed accidentally. Repeat acquisition procedure.
Safety devices in alarm state.
Excessive voltage drop.
Incorrect setting of parameters
and
.
Travel length error.
Maximum permitted travel
length exceeded
The radio transmission is im-
peded by metal structures and
reinforced concrete walls.
Flat batteries.
light wires disconnected.
Bulb blown or wires discon-
nected.
Incorrect setting of parameter
.
F2 fuse blown due to overvol-
tage.
Only for BH30/804/R. The gate
is moved by hand without being
unlocked, without mains and/or
battery voltage
ACTION
Function is restored automatically within 2 min.
If the problem persists, replace the control unit.
Wait for mains power to be restored.
Close the release handle and turn the key to the
close position. Check that the release contact is
connected correctly.
persists, replace the control unit.
Check the integrity of the connection cable.
Disconnect and reconnect the power supply.
Give a command (opening / step-by-step, ...).
If
is NOT displayed, repeat the acquisition
procedure.
If
is displayed again, contact the technical
service department.
Repeat acquisition procedure.
If the problem persists, check the cable connec-
ting the encoder to the motor.
Check if release handle is open.
Check that the motor turns without impediment. Con-
tact technical support in case of any problems.
Press the TEST button and check the safety
device/s in alarm state and the connections of
the safety devices.
Repeat acquisition procedure.
Check mains voltage.
Adjust parameters
and
weight and speed of the gate leaf.
Move gate into completely closed position (FC
limit switch signal must be active) and repeat the
procedure.
Check cable of limit switches. Replace the cable
if the problem persists.
Reset default controller unit parameters and repe-
at the procedure.
Stroke length less than the minimum allowed:
increase the length
Reduce the ride. Contact technical assistance
(travel exceeding the maximum allowed by the
technical characteristics)
Install the antenna outside.
Replace the transmitter batteries.
Check LED circuit and/or connector wires.
Check the bulb and/or wires.
Select the correct installation position with para-
meter
.
Replace the 2A F2 fuse.
WARNING: if B71/BC is used, check the correct
connection of the battery charger to the control
unit (the red cable [+] must be connected to the
POWER IN terminal 5, the black cable [-] must be
connected to the POWER IN terminal 4). Other-
wise, the manual manoeuvre will not be perfor-
med correctly.