Ingersoll Rand G330 Guía De Usuario Y Mantenimiento Manual página 87

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6, 7 lit.
16 lit.
10, 12 lit.
Oil level. Check
Ensure that the level lies between MIN and MAX
markings.
IMPORTANT! In continuous use the oil level
should be checked every 8 hours
When checking the oil level on a stationery engine,
read off the side of the dip stick marked "STOP" (at
earliest 3 minutes after engine stop).
A check can also be carried out when the engine is
running. Read off the dip stick side marked "OPERAT-
ING". (Does not apply for engines: TAD/TWD740GE,
TD/TAD420–721, TAD1030GE)
WARNING! Approaching or working on a run-
ning engine is dangerous. Watch out for rotating
components and hot surfaces.
Oil and oil filters. Replace
Always follow the recommended oil change interval
and always replace the oil filter at the same time. On
stationary engines do not remove the bottom plug.
Use an oil draining pump to suck up the oil.
1. Clean the oil filter bracket thoroughly to avoid dirt
ingress when the new filter/s are installed.
2. Run engine to normal operating temperature.
WARNING! Hot oil and hot surfaces can
cause burns.
3. Remove the bottom plug. Drain out engine oil.
4. Install the bottom plug together with a new gas-
ket.
5. Remove the filters (1) and the bypass filter
(2).where applicable. Check that the gaskets do
not remain on the engine.
5. Fill the new filters with engine oil and spread oil
on the gaskets. Screw the filter into place by
hand until the gasket touches. Then twist a fur-
ther half turn. No more!
6. Top up oil to correct level. Do not fill above the
MAX level.
7. Start the engine and let it idle. Check that the oil
pressure is normal.
8. Stop the engine. Check that there is no oil leak-
age around the filter. Top up if required.
Collect the old oil and oil filter and dispose of
them at a proper disposal point.
Maintenance
.
27

Publicidad

Tabla de contenido
loading

Tabla de contenido