Technical Data; General Data - Festo MPS 400 Serie Instrucciones De Utilizacion

Ocultar thumbs Ver también para MPS 400 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Measuring Pro Station – Operating instructions

7 Technical Data

7.1 General data

Parameter
Operating pressure
Operating voltage
Digital inputs/outputs
Inputs:
Outputs:
Analog inputs/outputs
Inputs:
Outputs:
IO link
Inputs:
Outputs:
Electrical connection
Pneumatic connection
Compressed air consumption at 600 kPa (continuous cycle)
Dimensions
Subject to change
20
14
4
1
0
1
6
Value
600 kPa (6 bar)
24 V DC, 4 A, ≤ 100 W output power, SELV/PELV limited
power supply (LPS)
Max. 24 V DC
Max. 2 A per output
Max. 4 A total
0...10 V DC
Max. 24 V DC
Max. 0.5 A per channel
Max 4 A per group C0-C3
3x 24-pin IEEE-488 sockets (SysLink)
RJ45 socket
Plastic tubing with 6 mm outside diameter
3 l/min
700 x 700 x 1160 mm
© Festo Didactic 8136944