Required equipment
Filter bag FSN 80 (option), for separation of dirt
particles > 80 µm
Filter bag FSN 1000 (option), for separation of
dirt particles > 1000 µm
Retaining ring for filter bag FSN 80/FSN 1000
Wet filter bag NFB
NOTICE
Submersible pump starts automatically when the container is full!
Submersible pump controlled by float: When the container is full, water is immediately pumped out
of the water outlet of the container when the mains plug of the vacuum cleaner is connected to a
plug socket.
1. Empty container before connecting the mains plug.
or
1. Before connecting the mains plug, connect the drain hose to the container and install it in such a
way that the escaping water cannot cause any damage.
Replace the filter cartridge with a foam filter:
See Fig. E.
1. Open latches.
2. Remove cover from the container.
3. Loosen locking screw on the bottom of the filter cartridge (E1).
4. Remove filter cartridge.
5. Carefully slip over main filter (foam) over the filter basket (E2).
6. Place cover on the container.
7. Close latches.
Place the filter bag FSN 80 or FSN 1000 in the container (option):
1. Place filter bag on the edge of the container and thread it into the intake socket.
2. Fix retaining ring with bayonet lock on the intake socket.
9 Filter bag is fixed.
Set up and connect the vacuum cleaner:
DANGER!
Risk of electric shock and flooding due to overflow of the container (siphon principle)!
1. Always place the vacuum cleaner above the water level.
1. Connect drain hose with Geka-
2. Install the drain hose in such a way that the escaping water cannot cause any damage.
3. Connect suction hose with hand tube and nozzle to the container.
30
Notes
For separating coarse dirt and liquid (pond cleaning, thread
algae), reusable, washable
For fixing the filter bag on the intake socket
For sludge extraction applications, for example during wet
drilling, wet grinding and wet cutting of stones, concrete or
masonry. For separation of sludge and liquid
or C-coupling
to the container.
1)
1)
Depending on model