Starmix NSG uClean PA-1455 KFG Instrucciones Para El Manejo página 35

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
Fault
Vacuum cleaner does not start
(when operating with submersible
pump)
Vacuum cleaner does not start
(when using a power tool)
Alarm signal of submersible pump
sounds
Submersible pump not running
Do not try anything else, contact customer services.
5 Maintenance
When maintaining and cleaning the vacuum cleaner, handle it in such a way that there is no danger for mainte-
nance personnel and other people. Before carrying out any maintenance work: Switch vacuum cleaner off and
pull mains plug out.
Replacing filter cartridge
See Fig. J.
1. Open latches.
2. Remove cover from the container.
Depending on model
1)
Cause
Switch in position A
Water sensor/floater has switched
off
Mains plug not in socket
Personal protection switch not
switched on
No mains voltage
Mains connection cable defective
Electrical tool not plugged into
socket on the vacuum cleaner
Switch not in position A
Float switch is stuck
Submersible pump blocked
Drain hose blocked
Submersible pump not plugged in
Thermal switch has tripped
Submersible pump blocked
Float switch is stuck
Remedy
Move switch to I
Empty container
Plug in
Switch on personal safety switch
Check fuse
Have it replaced
Plug mains plug into socket on the
vacuum cleaner
Move switch to A
Disconnect submersible pump,
make float switch moveable and
clean
Disconnect submersible pump,
remove foreign object from
housing and impeller
Clean drain hose
Insert plug of submersible pump
Disconnect submersible pump and
let it cool down. Eliminate cause
Disconnect submersible pump,
remove foreign object from
housing and impeller
Disconnect submersible pump,
make float switch moveable and
clean
en
35

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Nsg uclean pa-1455 kfg fw

Tabla de contenido