7.5 - Level 2 programming (adjustable parameters)

The adjustable parameters are factory set as shown in the Table 8 with: "
procedures, as there is a maximum time interval of 10 seconds between pressing one key and another; otherwise the system exits the procedure automatically
memorising the changes made up to that time .
Entrance led
Parameter
L1
Pause Time L1
L2
Step-by-
step
L3
Motor
speed
L4
Open Gate
Indicator
Output
L5
Motor
Force
L6
Partial
open
L7
Mainte-
nance
warning
8
TABLE 8 - Level two functions (adjustable parameters)
Led (level)
Value
5 seconds
L2
15 seconds
L3
30 seconds
L4
45 seconds
L5
60 seconds
L6
80 seconds
L7
120 seconds
L8
180 seconds
L1
Open - stop - close - stop
L2
Open - Stop - Close - Open
L3
Open - close - open - close
L4
Apartment block
L5
Apartment block 2 (more than 2" generates stop)
L6
Step-by-Step 2 (less than 2" causes partial opening)
L7
Hold-to-run
L8
"Semi-automatic" opening, "hold-to-run" closing
L1
Very slow
L2
Slow
L3
Medium
L4
Fast
L5
Very fast
L6
Extremely Fast
L7
Opens "Fast"; closes "slow"
L8
Opens "Extremely Fast" Closes "Fast"
L1
Open Gate Indicator Function
L2
On if gate closed
L3
On if gate open
L4
Active with 2nd radio output
L5
Active with 3rd radio output
L6
Active with 4th radio output
L7
Maintenance indicator
L8
Electric lock
L1
Super light gate
L2
"Very light" gate
L3
"Light" gate
L4
"Average" gate
L5
"Average heavy" gate
L6
"Heavy" gate
L7
"Very heavy" gate
L8
"Super heavy" gate
L1
0,5 mt
L2
1 mt
L3
1,5 mt
L4
2 mt
L5
2,5 mt
L6
3 mt
L7
3,4 mt
L8
4 mt
L1
Automatic (depending on the severity of the manoeuvre)
L2
1000
L3
2000
L4
4000
L5
7000
L6
10000
L7
15000
L8
20000
" but can be modified at any time as shown in Table 9 . Take care during modification
Description
Adjusts the pause time, namely the time
which lapses before automatic closure .
Is effective only if automatic closure is
enabled .
Manages the sequence of controls associ-
ated to the Step-by-Step input or to the
1st radio command .
Sets the motor speed during normal travel .
Adjusts the function associated with S .C .A .
output . (whatever the associated function
may be, the output supplies a voltage of
24V –30 +50% with a maximum power of
4W when active) .
The force control system also measures
the ambient temperature, automatically
increasing the force in the event of particu-
larly low temperatures .
Adjusts the measurement of the partial
opening . Partial opening can be controlled
with the 2nd radio command or with
"CLOSE", if the "Close" function is present,
this becomes "Open partially" .
Controls the number of manoeuvres after
which the automation maintenance notifi-
cation signal is sent (see paragraph 8 .2 .3
Maintenance notification).