Operating via AMS Device Manager
AMS Device Manager is a software package that monitors the process values, alarms and status
signals of the device. Please consult the operating instructions or online help for details on
using AMS Device Manager. You can find more information at: http://
www.emersonprocess.com/AMS/.
Electronic Device Description (EDD)
The HART EDD for SITRANS LR250 is labeled as supporting AMS Device Manager version 9.5.
See full operating instructions for further information on other versions of AMS.
Configuring a new device via AMS Device Manager
1)
Check the product page of our website at: www.siemens.com/LR250 to make sure you
have the most recent EDD. Go to Support > Software Downloads and if necessary
download it. Save the files to your computer, and extract the zipped file to an easily
accessed location.
2)
Launch AMS Device Manager– Add Device Type, browse to the unzipped EDD file and
select it.
3)
Launch AMS Device Manager. Application Guides for setting up HART devices with AMS
Device Manager can be downloaded from the product page of our website under Support
Maintenance
The radar device requires no maintenance or cleaning under normal operating conditions,
although periodic inspection and retightening of the attachment hardware may be required as
the gasket material will relax over time (dependant upon process conditions).
Under severe operating conditions, the antenna may require periodic cleaning. If cleaning
becomes necessary:
1)
Note the antenna material and the process medium, and select a cleaning solution that
will not react adversely with either.
2)
Remove the device from service and wipe the antenna clean using a cloth and suitable
cleaning solution.
Unit Repair and Excluded Liability
For detailed information, please see the inside back cover.
Antenna or electronics/enclosure replacement
If the antenna, lens, secondary o-ring, and spring washers require replacement due to damage
or failure, it may be replaced without the need for re-calibration if of the same type and size.
Replacing the antenna
• Changing to a different antenna type may be performed by a Siemens authorized repair
center or personnel.
• If the electronics or enclosure require replacement due to damage or failure, plesase
ensure the correct antenna version is used, otherwise a re-calibration will need to be
performed by Siemens authorized personnel.