11.6 Selection, configuration and
parameterisation of the controller
It takes two steps to set up the controller:
•
First: selection and configuration of the controller
type in the "setup" menu, "controller" submenu.
•
Second: parameterisation of the selected
controller type in "main menu", "controller"
submenu.
11.6.1 Selection and configuration of the controller
setup
controller
parameter 1
current
input
off
parameter 1
0-20 mA
proport. contrl.
4-20 mA
others
setpt
controller
off
setpoint
limit contact
contrl.
interpulse ctrl.
pulse freq. ctrl.
cont. controller
comp.
combined
controller
contrl.
off
interpulse ctrl.
pulse freq. ctrl.
cont. controller
controller
parameter 2
parameter 2
as controller
parameter 1
Fig. 30
Selection and configuration of the controller
•
In the "setup" menu, select the line "controller
parameter 1" or "controller parameter 2" using
the [Up] and [Down] buttons, and select the menu
with the same name using [OK].
36
prop. controller
interpulse ctrl.
pulse freq. ctrl.
cont. controller
low mA
high mA
Limit contact
downward viol.
upward violation
ctrl. direction
downward control
upward control
ctrl. direction
downward
control
upward control
ctrl. charact.
P
PI
PID
current
ctrl. charact.
input
P
0-20 mA
PI
4-20 mA
PID
others
for mA, select values
with [Up] and [Down]
buttons
low mA
high mA