Cleaning And Disinfection - Atos Medical Provox FreeHands Support Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
2. Instructions for Use
2.1 Preparation
Make sure the skin is clean and dry. To improve adhesion you may apply skin protection products, such as Provox Skin
Barrier, or adhesive supporting products such as Provox Silicone Glue, in accordance with their instructions for use.
2.2 Inspection procedures
Always inspect Provox FreeHands Support to make sure that it is not broken or worn out, see fig. 2. If any faults are
found during this check, the device must be discarded and not used.
2.3 Operating instructions
Preparation
Assemble the device by sliding FreeHands Support to the right over FreeHands Support Adhesive to fasten the locking
mechanism (fig. 3).
Several areas of the device are bendable for personal fit (fig. 4). To adjust FreeHands Support to your anatomy, place
the ring of FreeHands Support over the Provox hands-free speaking valve and hold the device to your sternum (cheast
bone). Identify any areas that require adjustment (fig. 5). Remove the device and bend FreeHands Support and FreeHands
Support Adhesive at the indicated folding areas to get a good personal fit (fig. 6-9).
Attachment
Keep FreeHands Support attached to FreeHands Support Adhesive. Remove the liner from the adhesive (fig. 10) and
place the ring over the Provox hands-free speaking valve (fig. 11). When aligned, press the FreeHands Support Adhesive
against your skin. Remove FreeHands Support and rub the adhesive in gentle circles to fix it to the sternum (fig. 12-14).
Reattach FreeHands Support by placing the ring over the Provox hands-free speaking valve and slide it to your left
into the locking mechanism while keeping the ring still (fig. 15).
Use
FreeHands Support can easily be removed and reattached as needed during the day. It is not necessary to remove
FreeHands Support Adhesive each time (fig. 15-16).
Removal
Remove Provox FreeHands Support by sliding FreeHands Support to your right while keeping the ring still over the
Provox hands-free speaking valve (fig. 16).
To remove FreeHands Support Adhesive grab at one end and pull it gently from the skin (fig. 17). If required use
Provox Adhesive Remover.

2.4 Cleaning and Disinfection

Clean FreeHands Support daily according to fig. 18-21 using drinking water and washing up liquid.
Disinfection might be needed if FreeHands Support looks dirty or there has been a risk of contamination. If disinfection
is needed, first clean the device as described above and then disinfect the device according to fig. 22.
8

Publicidad

Tabla de contenido
loading

Tabla de contenido