5.3. Settings

5.3.1. Setting the language

By default, the interface's language is the French. To change to English, please, follow the instructions below.
Press and hold the "MODE" and "OK" buttons simultaneously
very short time to enter the advanced menu."
A key (symbol of the "setting" menu) appears at the top right of the
LCD screen. It remains displayed all the time of presence in the
advanced menu and flashes on error.
Press "+" to display the menu "LANG. <> IDIOMA".
Press "OK" to validate the selection of the menu "LANG. <> IDIOMA".
Select the English language (EN) with the "+" or "-" button.
Confirm with the "OK" button. The interface now displays all menus and settings
in English.
Pressing the "MODE" button returns to the advanced menu selection screen.

5.3.2. Parameters to be set to match the configuration of the dwelling

The following parameters should be set:
Parameter
BATH*
Number of BATHROOM type exhaust grilles
WC*
Number of WC type exhaust grilles
Number of CELLAR type exhaust grilles
CELLAR*
(grilles installed in a cellar, laundry room or wash-up room).
BATHWC*
Number of BATHROOMWC type exhaust grilles (common)
ANTI-LEGIO
Anti-Legionella function (heats to 65°C once a week)
RAPID <> RISE
Heats the water in the tank faster
T.Flow ® Hygro+
PA
Adjusts the pressure to optimise operation in installation with
T.Flow
Hygro+
significant pressure drops
®
* Grilles connected to the water heater.
Note: If appropriate, the product will automatically detect the presence of a dual tariff (no configuration required).
The product adapts automatically to the types of grilles installed: humidity-controlled or self-balancing (no configuration
required).
LANGUAGE Menu
Description
53
and
Filter
or
Filter
Possible values
From 0 to 3 for T.Flow
®
Nano and from 0 to 6 for
T.Flow
Hygro+
®
No = the product does not
carry out an anti-Legionella
heating operation.
Yes = the product will carry
out an anti-Legionella heating
operation.
Yes or No
110 to 130 Pa per increments
of 5 Pa
EN
Factory
settings
1
1
0
0
No
Yes
110