9. FAULTS

9.1. With error code

If an error code appears on the screen, please contact your installer or maintenance company.
When an error occurs, it is possible to change mode or adjust the temperature setpoint. However, displaying the error takes
priority over the other displays.
If the fault relates to the heat pump, "SAFE" mode (back-up) is triggered automatically: the water is heated with the electrical
boost only. Some faults require the water heater to be shut down completely.
Message
Code displayed
displayed
SENSOR <>
Er01
TANK
SENSOR <>
Er02
T°BOT
SENSOR <>
Er03
T°TOP
SENSOR <>
Er04
T°HP
SENSOR <>
Er05
T°EVAP
SENSOR <>
Er06
T°AIR
FAN <>
Er07
ENGINE
SENSOR <>
Er08
PRESS <>
PCB
Er09
ANODE
COMM <>
Er10
COMP
Causes
The two water
temperature sensors (on
the top and bottom of the
tank) are defective or not
connected.
Water temperature sensor
at tank bottom defective.
Water temperature sensor
at tank top defective.
Refrigerating line
temperature sensor at
compressor outlet (HP)
defective.
Evaporator temperature
sensor defective.
Incoming air temperature
sensor (CMEV) defective.
Fan rotation speed
outside range.
Electronic board pressure
sensor defective.
Titanium anode board
alarm contact open: fault
on anode board.
Communication with
inverter module defective.
61
Consequences on the water heater
operation
Water not heating: stop heat pump and electrical boost.
Fan in operation (CMEV) for version
B200-FAN_T.FLOW HYGRO+ / B100-FAN_T.FLOW NANO
(with built-in fan).
Stop the heat pump and heat the water with electrical boost
only (SAFE mode).
Fan in operation (CMEV) for version
B200-FAN_T.FLOW HYGRO+ / B100-FAN_T.FLOW NANO
(with built-in fan).
Water heated with heat pump and electrical boost prohibited.
Fan in operation (CMEV) for version
B200-FAN_T.FLOW HYGRO+ / B100-FAN_T.FLOW NANO
(with built-in fan).
Stop the heat pump and heat the water with electrical boost
only (SAFE mode).
Fan in operation (CMEV) for version
B200-FAN_T.FLOW HYGRO+ / B100-FAN_T.FLOW NANO
(with built-in fan).
Stop the heat pump and heat the water with electrical boost
only (SAFE mode).
Stop the fan (no CMEV) for version B200-FAN_T.FLOW
HYGRO+ / B100-FAN_T.FLOW NANO (with built-in fan).
Water heated with heat pump and electrical boost.
Fan (CMEV) adjusted to fixed flow based on the set
configuration (number of exhaust grilles).
Water not heating: stop heat pump and electrical boost.
Fan in operation (CMEV) for version
B200-FAN_T.FLOW HYGRO+ / B100-FAN_T.FLOW NANO
(with built-in fan).
Stop the heat pump and heat the water with electrical boost
only (SAFE mode).
Fan in operation (CMEV) for version
B200-FAN_T.FLOW HYGRO+ / B100-FAN_T.FLOW NANO
(with built-in fan).